- Automated Liquid Handling
- Calorimetry
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color, Appearance & Physical tests
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Genomic (Nucleic acids)
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Material testing
- Metrology
- Microbiology (Clinical)
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Sample preparation
- Shakers and stirrers
- Spectrometry
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Toxicology
- Urine analysis
- Viscometry
- Water purification
- Weighing
- Sample preparation Microwave digestion
- UltraWAVE ECR upgrade - Microwave Digestion System
HOME / APPLICATIONS & TECHNIQUES /
UltraWAVE ECR upgrade - Microwave Digestion System
Reference: MIL-MCLA1001
https://www.analis.com/shop/mil-mcla1001-ultrawave-ecr-upgrade-microwave-digestion-system-23937 https://www.analis.com/web/image/product.template/23937/image_1920?unique=7370986SRC Technology
The ultraWAVE ECR is based on the SRC (Single Reaction Chamber technology), invented by Milestone several years ago (Patents pending).
SRC technology achieves extraordinary performance capabilities combining microwave heating with a high-pressure reactor which acts simultaneously as microwave cavity and vessel.
The ultraWAVE chamber is sealed, pressurized, heated, cooled, vented, and opened via a dedicated touch-screen control terminal.
Loading a rack of samples into the chamber is the only manual operation in an otherwise fully automated process of microwave-assisted sample preparation.
The outer surfaces of the vessel remain at room temperature throughout the entire microwave heating cycle.
As a result, the ultraWAVE is dramatically less labor intensive and easier to use compared to conventional microwave digestion systems.
- High performance. The highest temperatures & pressure capabilities and the fastest cooling time.
- Increased throughput. Double throughput of traditional microwave acid digestion instruments.
- No batching required. Simultaneous digestion of any sample type combination.
- Extra Corrosive Resistance. Use large amounts of HCl in open vessels without risk of corrosion!
- Ease of use. Cleaning of digestion vials is not necessary. No vessel assembly/disassembly.
- Expertise and Support. 30-years experience at your lab with the Milestone Connect.
- Compliance. USP 232/233 Chapters, ICH Q3D Guidelines and FDA regulation 21 CFR part 11.